TECHNICAL SPECIFICATION:
POWER
Model IPU-400-1E: 110 / 120 VAC, 50Hz / 60Hz
Model IPU-400-2E: 220 / 240VAC, 50Hz / 60Hz
Input power: ≤ 50VA
Accord with IEC 60601-1 standard, this device is in class I, continuous handling.
Ebi in effective area surface: 500μ W/cm2
Ebi max in effective area surface: 650μ W/cm2
Ebi average in effective area surface: 500μ W/cm2
Uniformity of Ebi: >0.4
Infrared radiation in effective area: <1mW/cm2(760nm<λ ≤ 1400nm=
Ultraviolet radiation in effective area: <1.0× 10-5mW/cm2 (180nm<λ ≤ 400nm=
Time display accuracy: 2h± 1min
Operate noise: ≤ 50dB(A)(ambit noise is lower than 40dB(A))
ENVIRONMENT CONDITION
Environment temperature
Operate temperature range: +10° C ~ +30° C
Storage temperature range: -40° C ~ +70° C
Environment humidity
Operate humidity range: 30%~75%
Storage humidity range: ≤ 80%
Transport and storage atmospheric pressure range: 500hPa~1060hPa
Input power
150VA
150VA
150VA
Light source
Blue light tube/LWS
Blue light tube
LED light
Tube quantity
5
5
------
Light source effective life
2000 hours
2000 hours
100,000 hours
Wave length
425nm-475nm
425nm-475nm
460nm-470nm
Light radiancy
≥ 550um/cm2
≥ 550um/cm2
≥ 2000um/cm2
Time display range
999hour,99min
999hour,99min
999hour,99min
Display time accuracy
2hour ± 1min
2hour ± 1min
2hour ± 1min
Adjust angle
30 ° , 60 ° , 90 °
------------------
----------
Adjust height
110mm-150mm
----------------
------------
With castor
yes
-----------
-------
Working environment
+10 °C -+30 °C
+10 °C -+30 °C
+10 °C -+30 °C
Package size
96*52*26cm
71*39*21cm
71*39*21cm
Gross weight
20kg
8kg
12kg
Company Information:
Â
Single-side & five blue lights
LED Digital Timer, display therapy time & total time
Lifting & Mobile Stand, radiant head rotating by angle of 30° / 60° /90°
Use LED light as lighting source, LED digital timer, display therapy time & total time
Hospital Baby Infant Phototherapy Unit
TECHNICAL SPECIFICATION:
POWER
Model IPU-400-1E: 110 / 120 VAC, 50Hz / 60Hz
Model IPU-400-2E: 220 / 240VAC, 50Hz / 60Hz
Input power: ≤ 50VA
Accord with IEC 60601-1 standard, this device is in class I, continuous handling.
Ebi in effective area surface: 500μ W/cm2
Ebi max in effective area surface: 650μ W/cm2
Ebi average in effective area surface: 500μ W/cm2
Uniformity of Ebi: >0.4
Infrared radiation in effective area: <1mW/cm2(760nm<λ ≤ 1400nm=
Ultraviolet radiation in effective area: <1.0× 10-5mW/cm2 (180nm<λ ≤ 400nm=
Time display accuracy: 2h± 1min
Operate noise: ≤ 50dB(A)(ambit noise is lower than 40dB(A))
ENVIRONMENT CONDITION
Environment temperature
Operate temperature range: +10° C ~ +30° C
Storage temperature range: -40° C ~ +70° C
Environment humidity
Operate humidity range: 30%~75%
Storage humidity range: ≤ 80%
Transport and storage atmospheric pressure range: 500hPa~1060hPa
Input power
150VA
150VA
150VA
Light source
Blue light tube/LWS
Blue light tube
LED light
Tube quantity
5
5
------
Light source effective life
2000 hours
2000 hours
100,000 hours
Wave length
425nm-475nm
425nm-475nm
460nm-470nm
Light radiancy
≥ 550um/cm2
≥ 550um/cm2
≥ 2000um/cm2
Time display range
999hour,99min
999hour,99min
999hour,99min
Display time accuracy
2hour ± 1min
2hour ± 1min
2hour ± 1min
Adjust angle
30 ° , 60 ° , 90 °
------------------
----------
Adjust height
110mm-150mm
----------------
------------
With castor
yes
-----------
-------
Working environment
+10 °C -+30 °C
+10 °C -+30 °C
+10 °C -+30 °C
Package size
96*52*26cm
71*39*21cm
71*39*21cm
Gross weight
20kg
8kg
12kg
Company Information:
Â