(3)Energy selection: 0, 3, 5, 7, 10, 20, 30, 50, 100, 200, 300, 360 joules (nominal at a resistance of 50)
(4)Charging time: Maximum 10 seconds to 360 Joules
(5)Standard Adult/Pediatric Paddles  Reusable external adult paddles (pediatric paddles integrated) Â
7" color LCD display
Monophasic defibrillator / monitor
ECG
ECG lead: I, II, III,, a VR, a VL, a VF, V1-V6
S-T segment analysis: -2.0-2.0mv
Protection: withstand 4000v AV/50HZ voltage in isolation and work against lectrosurgicalÂ
interence and defibrillation.
ECG lead/cable: general lead/cable for adult, pediatric and neonatal patients
Respiration
Measurement method: Thoracic impedanceÂ
NIBP:
Method: automatic oscillation
Working mode: manual/automatic
Measur:Â adult:Â 10-250mmHg
Ement:Â pediatric:Â 10-200mmHg
Rabge:Â neonatal:Â 10-135mmHg
TEMP:
Measurement range: 20-45ºC
Resolution: 0.1ºC
SpO2:
Display: SpO2 value, pulse histogram, waveform, pulse
Range: 0-99% for adult, pediatric and neonatal patients
Probe: stand: adult finger clip Optional: pediatric Y-type clip and neonatal wrap
Pulse:
Pulse range: 0-300bpm
Pulse accuracy: ±2bpm
Â
ECG
Â
ECGÂ lead
 I, II, III,, a VR, a VL, a VF, V1-V6
S-T segment analysis
 -2.0-2.0mv
Protection
 withstand 4000v AV/50HZ voltage in isolation and work against lectrosurgicalÂ
interence and defibrillation.
ECGÂ lead/cable
 general lead/cable for adult, pediatric and neonatal patientsÂ
Respiration
Â
Measurement method
 Thoracic impedance
NIBP
Â
Method
 automatic oscillation
Working mode
 manual/automatic
Measur
 Adult 10-250mmHg
Ement
 Pediatric 10-200mmHg
Rabge
 Neonatal 10-135mmHg
TEMP
Â
Measurement range
 20-45ºC
Resolution
 0.1ºC
SpO2
Â
Display
 SpO2 value, pulse histogram, waveform, pulse
Range
 0-99% for adult, pediatric and neonatal patients
Probe
 stand adult finger clip Optional pediatric Y-type clip and neonatal wrap
Pulse
Â
Pulse range
 0-300bpm
Pulse accuracy
 ±2bpm
High quality ensured : We are real manufacturer,not trading company.
The raw material for strip used we used are imported from Japan, German and UK.
We guarantee all our item are made with finest quality ,all products will be checked
Company ' s competition:We are the only manufacturer can produce 100*30cm
uncut urine test strips in China so far
The world`s leading fully automatic production equipment