Incubation tank gas jacket water jacket two types of heating

According to the heating method, it is divided into two types: gas sleeve and water jacket:

Both air jacketed and water jacketed, both heating systems are accurate and reliable, and they all have their own advantages and disadvantages. Water jacket heating maintains a constant temperature by enclosing an internal tank through a separate water jacket. The advantage is that water is a good thermal insulation material. When a power failure occurs, the water jacket system can Keeping the temperature accuracy and stability in the incubator for a long time is beneficial to users who are not stable in the experimental environment and need to maintain stable culture conditions for a long time. The gas-sleeve heating is to directly heat the inner tank through the heaters in the gas jacket of the tank, and is also called direct heating on six sides. Compared with the water jacket type, the gas-sleeve type has the characteristics of quick heating and rapid recovery of the temperature than the water-type incubator, which is particularly advantageous for short-term cultivation and the need for frequent switching of the door. In addition, the air-sleeve design is simpler for the user than the water jacket type.

Maintaining a constant temperature in the carbon dioxide incubator is an important factor in maintaining healthy cell growth, so an accurate and reliable temperature control system is an integral part of the incubator. In order to make the incubator work more stably, we recommend that users choose a carbon dioxide incubator with independent triple temperature control functions, namely temperature control inside the box, over temperature alarm control and ambient temperature monitoring.

Precautions for use

1. Close the door of the incubator to prevent gas leakage and affect the test results;

2. After the refrigeration system stops working, wipe the working chamber and the glass observation window with a soft cloth;

3. Before each stop, each control switch should be in the non-working state to cut off the power;

4. The carbon dioxide incubator should be placed on a flat surface, and the environment should be clean and tidy, dry and ventilated;

5. Do not adjust the pressure of the inflowing gas to an excessive level to avoid breaking the pipeline and damaging the detector;

6. Before using the instrument, each control switch should be in non-working state, and the speed control knob should be placed in the minimum position;

7. Proper use and attention to the maintenance of the instrument, so that it is in good working condition, can extend the life of the instrument;

8. Not applicable to the cultivation of articles containing volatile chemical solvents, low concentrations of explosive gases and low ignition gases, and toxic substances.

9. Keep the air in the incubator clean and disinfect regularly; always pay attention to the amount of distilled water in the distillation tank to keep the relative humidity inside the tank while avoiding evaporation of the culture solution;

10. During continuous operation, the instrument should be regularly inspected every three months; check for water droplets, dirt, etc. falling into the motor and exposed refrigeration components; cleaning dust and dirt on the compressor and condenser; Fuses, control elements and fastening screws.